pyFroniusReg/examples/force_charge.py

46 lines
1.4 KiB
Python
Executable file

#!/usr/bin/env python3
from pyfroniusreg import gen24_registers
from pymodbus.client.tcp import ModbusTcpClient
fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10)
fronius1.connect()
soc = gen24_registers.scaledChaState.get(fronius1)
print(" SOC: %s%%" % soc)
discharge = gen24_registers.scaledOutWRte.get(fronius1)
print("Pre DRate: %d%%" % discharge)
charge = gen24_registers.scaledInWRte.get(fronius1)
print("Pre CRate: %d%%" % charge)
mode = gen24_registers.StorCtl_Mod.get(fronius1)
print("Pre Mode: %d" % mode)
timeout = gen24_registers.InOutWRte_RvrtTms.get(fronius1)
print ("Timer: %d" % timeout)
# Set timer for 2 minutes
err = gen24_registers.InOutWRte_RvrtTms.set(fronius1, 120)
# This should be 'limit discharge' mode
print("Setting control mode to limit discharge")
err = gen24_registers.StorCtl_Mod.set(fronius1, 2)
# Charge battery at a rate from -2% discharge to 100% charge
# as a percentage of the MaxChaRte, which in our case is 25600W
print("Setting discharge rate to -10%")
err = gen24_registers.scaledOutWRte.set(fronius1, int(-10))
print("Setting charge rate to 100%")
err = gen24_registers.scaledInWRte.set(fronius1, int(100))
discharge = gen24_registers.scaledOutWRte.get(fronius1)
print("Post DRate: %d%%" % discharge)
charge = gen24_registers.scaledInWRte.get(fronius1)
print("Post CRate: %d%%" % charge)
mode = gen24_registers.StorCtl_Mod.get(fronius1)
print("Post Mode: %d" % mode)