#!/usr/bin/env python3
#from PyFroniusReg import froniusreg
#import src.froniusreg
import src.pyfroniusreg.froniusreg as froniusreg
from pymodbus.client.tcp import ModbusTcpClient
fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10)
fronius1.connect()
soc = froniusreg.scaledStateOfCharge.getValue(fronius1)
print(" SOC: %s%%" % soc)
discharge = froniusreg.scaledOutWRte.getValue(fronius1)
print("Pre DRate: %d%%" % discharge)
charge = froniusreg.scaledInWRte.getValue(fronius1)
print("Pre CRate: %d%%" % charge)
mode = froniusreg.StorCtl_Mode.getValue(fronius1)
print("Pre Mode: %d" % mode)
reserve = froniusreg.scaledReserve.getValue(fronius1)
print("Pre Res: %d" % reserve)
rate = froniusreg.scaledMaxChaRte.getValue(fronius1)
print("Pre rate: %d" % rate)
rate = froniusreg.scaledMaxWChaGra.getValue(fronius1)
print("Pre WGra rate: %d" % rate)
revert = froniusreg.InOutWRte_RvrtTms.getValue(fronius1)
print("Timer: %d" % revert)