pyFroniusReg/examples/reset_charge.py

51 lines
1.5 KiB
Python
Executable file

#!/usr/bin/env python3
from pyfroniusreg import gen24_registers
from pymodbus.client.tcp import ModbusTcpClient
fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10)
fronius1.connect()
soc = gen24_registers.scaledChaState.get(fronius1)
print(" SOC: %s%%" % soc)
discharge = gen24_registers.scaledOutWRte.get(fronius1)
print("Pre DRate: %d%%" % discharge)
charge = gen24_registers.scaledInWRte.get(fronius1)
print("Pre CRate: %d%%" % charge)
mode = gen24_registers.StorCtl_Mod.get(fronius1)
print("Pre Mode: %d" % mode)
reserve = gen24_registers.scaledMinRsvPct.get(fronius1)
print("Pre Res: %d" % reserve)
timeout = gen24_registers.InOutWRte_RvrtTms.get(fronius1)
print (" Timer: %d" % timeout)
# Reset timer
err = gen24_registers.InOutWRte_RvrtTms.set(fronius1, 0)
# This should be 'no limits' mode
err = gen24_registers.StorCtl_Mod.set(fronius1, 0)
# discharge at 100% allowed charge rate
err = gen24_registers.scaledOutWRte.set(fronius1, 100)
err = gen24_registers.scaledInWRte.set(fronius1, 100)
# charge to 7%
err = gen24_registers.scaledMinRsvPct.set(fronius1, 7)
discharge = gen24_registers.scaledOutWRte.get(fronius1)
print("Post DRate: %d%%" % discharge)
charge = gen24_registers.scaledInWRte.get(fronius1)
print("Post CRate: %d%%" % charge)
mode = gen24_registers.StorCtl_Mod.get(fronius1)
print("Post Mode: %d" % mode)
reserve = gen24_registers.scaledMinRsvPct.get(fronius1)
print("Post Res: %d" % reserve)
timeout = gen24_registers.InOutWRte_RvrtTms.get(fronius1)
print (" Timer: %d" % timeout)