#!/usr/bin/env python3 from pyfroniusreg import gen24_registers from pymodbus.client.tcp import ModbusTcpClient fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10) fronius1.connect() soc = gen24_registers.scaledChaState.get(fronius1) print(" SOC: %s%%" % soc) discharge = gen24_registers.scaledOutWRte.get(fronius1) print("Pre DRate: %d%%" % discharge) charge = gen24_registers.scaledInWRte.get(fronius1) print("Pre CRate: %d%%" % charge) mode = gen24_registers.StorCtl_Mod.get(fronius1) print("Pre Mode: %d" % mode) reserve = gen24_registers.scaledMinRsvPct.get(fronius1) print("Pre Res: %d" % reserve) timeout = gen24_registers.InOutWRte_RvrtTms.get(fronius1) print (" Timer: %d" % timeout) # Reset timer err = gen24_registers.InOutWRte_RvrtTms.set(fronius1, 0) # This should be 'no limits' mode err = gen24_registers.StorCtl_Mod.set(fronius1, 0) # discharge at 100% allowed charge rate err = gen24_registers.scaledOutWRte.set(fronius1, 100) err = gen24_registers.scaledInWRte.set(fronius1, 100) # charge to 7% err = gen24_registers.scaledMinRsvPct.set(fronius1, 7) discharge = gen24_registers.scaledOutWRte.get(fronius1) print("Post DRate: %d%%" % discharge) charge = gen24_registers.scaledInWRte.get(fronius1) print("Post CRate: %d%%" % charge) mode = gen24_registers.StorCtl_Mod.get(fronius1) print("Post Mode: %d" % mode) reserve = gen24_registers.scaledMinRsvPct.get(fronius1) print("Post Res: %d" % reserve) timeout = gen24_registers.InOutWRte_RvrtTms.get(fronius1) print (" Timer: %d" % timeout)