Adjust examples to generated registers

This commit is contained in:
Paul Warren 2024-10-16 21:33:28 +11:00
parent 24022a04ea
commit a2a6b9c4e9
4 changed files with 18 additions and 18 deletions

View file

@ -14,15 +14,15 @@ fronius1.connect()
current_time = datetime.now() current_time = datetime.now()
soc = gen24_registers.scaledStateOfCharge.get(fronius1) soc = gen24_registers.scaledChaState.get(fronius1)
charge_data = [] charge_data = []
discharge_data = [] discharge_data = []
print("Gathering 20 second average of battery Charge") print("Gathering 20 second average of battery Charge")
while( (datetime.now() - current_time).seconds < 20): while( (datetime.now() - current_time).seconds < 20):
charge_data.append(gen24_registers.scaledToBattery.get(fronius1)) charge_data.append(gen24_registers.scaledmodule_3_DCW.get(fronius1))
discharge_data.append(gen24_registers.scaledFromBattery.get(fronius1)) discharge_data.append(gen24_registers.scaledmodule_4_DCW.get(fronius1))
avg_charge = statistics.mean(charge_data) avg_charge = statistics.mean(charge_data)
avg_discharge = statistics.mean(discharge_data) avg_discharge = statistics.mean(discharge_data)

View file

@ -7,7 +7,7 @@ from pymodbus.client.tcp import ModbusTcpClient
fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10) fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10)
fronius1.connect() fronius1.connect()
soc = gen24_registers.scaledStateOfCharge.get(fronius1) soc = gen24_registers.scaledChaState.get(fronius1)
print(" SOC: %s%%" % soc) print(" SOC: %s%%" % soc)
discharge = gen24_registers.scaledOutWRte.get(fronius1) discharge = gen24_registers.scaledOutWRte.get(fronius1)
@ -16,12 +16,12 @@ print("Pre DRate: %d%%" % discharge)
charge = gen24_registers.scaledInWRte.get(fronius1) charge = gen24_registers.scaledInWRte.get(fronius1)
print("Pre CRate: %d%%" % charge) print("Pre CRate: %d%%" % charge)
mode = gen24_registers.StorCtl_Mode.get(fronius1) mode = gen24_registers.StorCtl_Mod.get(fronius1)
print("Pre Mode: %d" % mode) print("Pre Mode: %d" % mode)
# This should be 'limit discharge' mode # This should be 'limit discharge' mode
print("Setting control mode to limit discharge") print("Setting control mode to limit discharge")
err = gen24_registers.StorCtl_Mode.set(fronius1, 2) err = gen24_registers.StorCtl_Mod.set(fronius1, 2)
# Charge battery at a rate from -2% discharge to 100% charge # Charge battery at a rate from -2% discharge to 100% charge
# as a percentage of the MaxChaRte, which in our case is 25600W # as a percentage of the MaxChaRte, which in our case is 25600W
@ -36,5 +36,5 @@ print("Post DRate: %d%%" % discharge)
charge = gen24_registers.scaledInWRte.get(fronius1) charge = gen24_registers.scaledInWRte.get(fronius1)
print("Post CRate: %d%%" % charge) print("Post CRate: %d%%" % charge)
mode = gen24_registers.StorCtl_Mode.get(fronius1) mode = gen24_registers.StorCtl_Mod.get(fronius1)
print("Post Mode: %d" % mode) print("Post Mode: %d" % mode)

View file

@ -11,10 +11,10 @@ fronius1.connect()
print(" Manufacturer: %s" % gen24_registers.Mn.get(fronius1)) print(" Manufacturer: %s" % gen24_registers.Mn.get(fronius1))
print(" Model: %s" % gen24_registers.Md.get(fronius1)) print(" Model: %s" % gen24_registers.Md.get(fronius1))
print(" Version: %s" % gen24_registers.Vr.get(fronius1)) print(" Version: %s" % gen24_registers.Vr.get(fronius1))
print(" SOC: %s%%" % gen24_registers.scaledStateOfCharge.get(fronius1)) print(" SOC: %s%%" % gen24_registers.scaledChaState.get(fronius1))
print("Max DCharg Rate: %d%%" % gen24_registers.scaledOutWRte.get(fronius1)) print("Max DCharg Rate: %d%%" % gen24_registers.scaledOutWRte.get(fronius1))
print("Max Charge Rate: %d%%" % gen24_registers.scaledInWRte.get(fronius1)) print("Max Charge Rate: %d%%" % gen24_registers.scaledInWRte.get(fronius1))
print(" Reserve: %d%%" % gen24_registers.scaledReserve.get(fronius1)) print(" Reserve: %d%%" % gen24_registers.scaledMinRsvPct.get(fronius1))
print("Max Charge rate: %dW" % gen24_registers.scaledMaxChaRte.get(fronius1)) print("Max Charge rate: %dW" % gen24_registers.scaledMaxChaRte.get(fronius1))
print(" Current charge: %dW" % gen24_registers.scaledToBattery.get(fronius1)) print(" Current charge: %dW" % gen24_registers.scaledmodule_3_DCW.get(fronius1))
print(" Current dCharg: %dW" % gen24_registers.scaledFromBattery.get(fronius1)) print(" Current dCharg: %dW" % gen24_registers.scaledmodule_4_DCW.get(fronius1))

View file

@ -7,7 +7,7 @@ from pymodbus.client.tcp import ModbusTcpClient
fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10) fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10)
fronius1.connect() fronius1.connect()
soc = gen24_registers.scaledStateOfCharge.get(fronius1) soc = gen24_registers.scaledChaState.get(fronius1)
print(" SOC: %s%%" % soc) print(" SOC: %s%%" % soc)
discharge = gen24_registers.scaledOutWRte.get(fronius1) discharge = gen24_registers.scaledOutWRte.get(fronius1)
@ -16,20 +16,20 @@ print("Pre DRate: %d%%" % discharge)
charge = gen24_registers.scaledInWRte.get(fronius1) charge = gen24_registers.scaledInWRte.get(fronius1)
print("Pre CRate: %d%%" % charge) print("Pre CRate: %d%%" % charge)
mode = gen24_registers.StorCtl_Mode.get(fronius1) mode = gen24_registers.StorCtl_Mod.get(fronius1)
print("Pre Mode: %d" % mode) print("Pre Mode: %d" % mode)
reserve = gen24_registers.scaledReserve.get(fronius1) reserve = gen24_registers.scaledMinRsvPct.get(fronius1)
print("Pre Res: %d" % reserve) print("Pre Res: %d" % reserve)
# This should be 'no limits' mode # This should be 'no limits' mode
err = gen24_registers.StorCtl_Mode.set(fronius1, 0) err = gen24_registers.StorCtl_Mod.set(fronius1, 0)
# discharge at 100% allowed charge rate # discharge at 100% allowed charge rate
err = gen24_registers.scaledOutWRte.set(fronius1, 100) err = gen24_registers.scaledOutWRte.set(fronius1, 100)
err = gen24_registers.scaledInWRte.set(fronius1, 100) err = gen24_registers.scaledInWRte.set(fronius1, 100)
# charge to 7% # charge to 7%
err = gen24_registers.scaledReserve.set(fronius1, 7) err = gen24_registers.scaledMinRsvPct.set(fronius1, 7)
discharge = gen24_registers.scaledOutWRte.get(fronius1) discharge = gen24_registers.scaledOutWRte.get(fronius1)
print("Post DRate: %d%%" % discharge) print("Post DRate: %d%%" % discharge)
@ -37,8 +37,8 @@ print("Post DRate: %d%%" % discharge)
charge = gen24_registers.scaledInWRte.get(fronius1) charge = gen24_registers.scaledInWRte.get(fronius1)
print("Post CRate: %d%%" % charge) print("Post CRate: %d%%" % charge)
mode = gen24_registers.StorCtl_Mode.get(fronius1) mode = gen24_registers.StorCtl_Mod.get(fronius1)
print("Post Mode: %d" % mode) print("Post Mode: %d" % mode)
reserve = gen24_registers.scaledReserve.get(fronius1) reserve = gen24_registers.scaledMinRsvPct.get(fronius1)
print("Post Res: %d" % reserve) print("Post Res: %d" % reserve)