diff --git a/src/pyfroniusreg/gen24_registers.py b/src/pyfroniusreg/gen24_registers.py index e31bb42..3f160e0 100644 --- a/src/pyfroniusreg/gen24_registers.py +++ b/src/pyfroniusreg/gen24_registers.py @@ -16,6 +16,9 @@ Vr = froniusreg.FroniusReg(40045, froniusreg.string8, 1, "SW version") SN = froniusreg.FroniusReg(40068, froniusreg.string16, 1, "Serial Number") DA = froniusreg.FroniusReg(40069, froniusreg.uint16, 1, "Modbus Device Address") +InputID = froniusreg.FroniusReg(40304, froniusreg.uint16, 1, "Input ID") +InputIDString = froniusreg.FroniusReg(40305, froniusreg.string8, 1, "Input ID String") + OutWRte = froniusreg.FroniusReg(40366, froniusreg.int16, 1, "DischargeRate") InWRte = froniusreg.FroniusReg(40367, froniusreg.int16, 1, "ChargeRate") WRteSF = froniusreg.FroniusReg(40379, froniusreg.int16, 1, "ScalingFactor for storage Watts")