pyFroniusReg/examples/force_charge.py

38 lines
1.1 KiB
Python
Raw Normal View History

2024-10-08 16:32:55 +11:00
#!/usr/bin/env python3
2024-10-09 16:48:34 +11:00
from froniusreg import froniusreg
2024-10-08 16:32:55 +11:00
from pymodbus.client.tcp import ModbusTcpClient
fronius1 = ModbusTcpClient("172.19.107.211", port=502, timeout=10)
fronius1.connect()
soc = FroniusReg.scaledStateOfCharge.getValue(fronius1)
print(" SOC: %s%%" % soc)
discharge = FroniusReg.scaledOutWRte.getValue(fronius1)
print("Pre DRate: %d%%" % discharge)
charge = FroniusReg.scaledInWRte.getValue(fronius1)
print("Pre CRate: %d%%" % charge)
mode = FroniusReg.StorCtl_Mode.getValue(fronius1)
print("Pre Mode: %d" % mode)
# This should be 'limit discharge' mode
err = FroniusReg.StorCtl_Mode.setValue(fronius1, 2)
# Charge battery at a rate from -2% discharge to 100% charge
# as a percentage of the MaxChaRte, which in our case is 25600W
err = FroniusReg.scaledOutWRte.setValue(fronius1, -10)
err = FroniusReg.scaledInWRte.setValue(fronius1, 100)
discharge = FroniusReg.scaledOutWRte.getValue(fronius1)
print("Post DRate: %d%%" % discharge)
charge = FroniusReg.scaledInWRte.getValue(fronius1)
print("Post CRate: %d%%" % charge)
mode = FroniusReg.StorCtl_Mode.getValue(fronius1)
print("Post Mode: %d" % mode)